TCAT-2 Temperature Controller

Model:TCAT-2

 TCAT-2 Temperature Controller "Animal Temperature Controller"

  • Details
  • Specifications
  • Applications
  • Support
  •  TCAT-2 Temperature Controller with RET-3 Temperature probe and HL-1, Heat Lamp

    Our new TCAT-2 family of general purpose PID Autotuning Controllers provides accurate temperature control in a variety of laboratory applications. Combined with a heat lamp or heating pad, the TCAT-2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures. Small animal cages are easily warmed with a heat lamp. The TCAT-2 may also be used in cooling applications, such as to control independent perfusate cooling systems. Realizing that laboratory applications are diverse, Physitemp can provide several versions of the TCAT Controller. The model specified depends on whether a laboratory has a general or specific need for the controller:

    TCAT-2AC:
    This version controls only AC powered heating or cooling devices such as a heat lamp. It is the least costly.

    TCAT-LV:
    This model provides a low-voltage DC output for electrically sensitive applications where AC frequencies might interfere with other monitoring devices. It comes standard with a built in DC power supply designed to operate with our HP-1M Heating Plate for small rodents. The TCAT-2LV utilizes a dual set point control circuit to prevent a heating element from overshooting the control point due to thermal lag in the control system. This is an important feature in preventing burns due to incorrect control settings or faulty feedback sensor. On a custom basis, we can provide a variety of DC power supplies Depending on the load power requirements.

    TCAT-2DF:
    This is a combination version which includes both an AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low-noise" DC output for heating pads. This version allows you to control a variety of different loads.

    All TCAT-2 versions may be used with any of our extensive line of accurate Type T thermocouple probes, which act as the temperature feedback sensor. Most commonly used are the RET series of animal rectal probes, but the IT series of implantable flexible probes and MT series of needle probes may also be used depending on the specific application. All instruments are designed to operate on a 110V or 230V AC supply.

    The unit comes in a durable baked enamel painted aluminum housing. Adjustable front feet allow the user to raise the front of controller to provide a more convenient viewing angle.

    A heat/cool switch is provided when using the controller with cooling devices such as small refrigeration compressors or thermoelectric stages. In the cooling mode it inverts the control function and shuts off the load when feedback sensor temperature falls below the set point. A small lamp on the front of the control unit indicates when power is being applied to the load.

    The TCAT-2 is simple to set-up; connect the feedback sensor to the animal and to the back of the controller, connect the heating pad, blanket, lamp or cooling device to the appropriate outlet on the rear of the controller. Adjust the set temperature as required (lower green display) according to the instruction label on top of the instrument. The set temperature is stored in memory after the unit is switched off.

    Features

    Controls heating blankets heat lamps or heating pad.

    Can be used for both heating and cooling applications.

    110 to 230V AC line operation

    Control Range of -100 to +400°C

    Resolution 0.1°C

  •  

     

    Specifications

    Resolution

     

    ±0.1°C

    Accuracy

     

    ± 0.5°C

    Range

     

    Ambient +2° to 60°C

    Readout

     

    Dual display of Set (red) and Run(red) temperatures

    Max AC Power Output with resistive load

     

    700 watts (Does not apply to TCAT-2LV)

    DC Output Rating:

     

    TCAT-2DF and TCAT-2LV: 12V DC, 2 Amps Max. Custom output voltages available upon request(Does not apply to TCAT-2AC)

    AC ground leakage current

     

    less than 1 millamp at 110 V AC

    Dual Setpoint Protection Feature

     

    TCAT-2DF and TCAT-2LV onlyadditional heating pad feedback sensor prevents temperature exceeding 45°C.

    Dimensions

     

    7 1/4" W x 4 3/8" H x 10" D

    Weight

     

    Less than 5 lbs.

    Power Supply

     

    110V or 220 V AC

  •  Please call for details 

  •  Please call for details 

ICP備案號: 滬ICP備15057650號-1 滬公網安備31011202005471
雷萌生物科技(上海)有限公司 保留所有版權.

首頁   |   產品中心   |   產品應用   |   技術支持   |   新聞中心   |   關于我們   |   ibidi官網
主站蜘蛛池模板: 亚洲成人网在线观看| 亚洲品质国产精品无码| 色噜噜狠狠色综合网图区| 亚洲欧美国产五月天综合| 中文成人无码国产亚洲| 在线国产综合一区二区三区| 91人妻日韩人妻无码专区精品| 国产Av无码精品色午夜| 国产免费怡红院视频| 亚洲香蕉久久| 国产麻豆91网在线看| 欧美日韩导航| 精品五夜婷香蕉国产线看观看| 在线观看视频99| 黄色网在线| 国产精品999在线| 国产香蕉97碰碰视频VA碰碰看| 欧美综合一区二区三区| 日韩在线影院| 日韩精品无码免费一区二区三区 | 国产原创演绎剧情有字幕的| av大片在线无码免费| 久久精品娱乐亚洲领先| 亚洲精品国偷自产在线91正片| 激情综合婷婷丁香五月尤物 | 国产成本人片免费a∨短片| 波多野结衣亚洲一区| 在线视频一区二区三区不卡| 亚洲欧美天堂网| 欧美人在线一区二区三区| 好久久免费视频高清| 四虎永久在线精品影院| 国产夜色视频| 国产精品.com| 国产精品偷伦视频免费观看国产 | 久久人搡人人玩人妻精品一| 手机看片1024久久精品你懂的| 九九热精品免费视频| 国产主播一区二区三区| 高清视频一区| 青青草原国产免费av观看| 日韩在线2020专区| 国产91小视频| 亚洲人成日本在线观看| 欧美天天干| 亚洲一区免费看| AV不卡国产在线观看| 中文字幕丝袜一区二区| 五月婷婷综合网| 婷婷色狠狠干| 欧美第二区| 亚洲第一在线播放| 国产成年女人特黄特色毛片免| 亚洲国产成人精品无码区性色| 亚洲国产第一区二区香蕉| 欧美激情网址| 欧美区一区| 在线免费亚洲无码视频| 91在线激情在线观看| 亚洲高清中文字幕在线看不卡| 一本大道无码日韩精品影视| 四虎成人精品在永久免费| 国产男女免费完整版视频| 国产成人亚洲精品蜜芽影院| 国产一国产一有一级毛片视频| 久久香蕉国产线看观看式| 蜜桃臀无码内射一区二区三区| 国产精品香蕉| 真实国产精品vr专区| 国产一级妓女av网站| 国产丝袜啪啪| 亚洲精品麻豆| 国产香蕉97碰碰视频VA碰碰看| 婷婷久久综合九色综合88| 精品久久久久无码| 国产成人乱无码视频| 天堂成人av| 欧美精品1区| 91国内外精品自在线播放| 日韩av手机在线| 中文字幕在线一区二区在线| 欧洲欧美人成免费全部视频|